Loading...

2018 irc roof sheathing requirements

CHAPTER 8 ROOF-CEILING CONSTRUCTION. Asphalt shingle packaging shall bear a. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, The 24 inch measurement shall be along the, Building-integrated photovoltaic products. The installation of slate shingles shall comply with the provisions of this section. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Asphalt shingle packaging shall bear a. Asphalt shingles shall be used only on roof. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Sprayed polyurethane foam roofs shall have a design. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than inch (19.1 mm) into the roof sheathing. Wood shingles shall be laid with a side lap not less than 1, Roof flashing shall be not less than No. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. PDF 2018 International Residential Code Changes Related to Wood Construction Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, In areas where the average daily temperature in January is 25F (-4C) 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Sprayed polyurethane foam roofs shall have a design. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. The ratio changes based on climate severity. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Liquid-applied roofing shall comply with ASTM C 836, C 957, D 1227, D 3468, D 6083, D 6694 or D 6947. SECTION R804 COLD-FORMED STEEL ROOF FRAMING. Liquid-applied roofing shall have a design. Self-adhering polymer-modified bitumen. The installation of wood shingles shall comply with the provisions of this section. or less. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. R905.2Asphalt shingles. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be tested in accordance with ASTM D7158. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Stainless steel fasteners are acceptable for metal roofs. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. Roof Deck Requirements for Installation of Asphalt Shingles Technical . Chapter 9: Roof Assemblies, 2015 IRC portion of the 2018 CT - UpCodes 233 0 obj <>/Filter/FlateDecode/ID[<4D23A6406EEE004484C52F82EDD55E2A>]/Index[201 60]/Info 200 0 R/Length 141/Prev 323429/Root 202 0 R/Size 261/Type/XRef/W[1 3 1]>>stream Stainless steel fasteners are acceptable for metal roofs. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Liquid-applied roofing shall have a design. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Slate shingles shall be fastened to solidly sheathed roofs. The installation of asphalt shingles shall comply with the provisions of this section. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Mineral-surfaced roll roofing shall not be applied on roof. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. References are to the 2018 International Residential Code (sections are designated as R). Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. The installation of wood shingles shall comply with the provisions of this section. The installation of wood shingles shall comply with the provisions of this section. Galvanized fasteners shall be used for steel roofs. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Asphalt shingles shall be used only on roof. The installation of asphalt shingles shall comply with the provisions of this section. Slate shingles shall comply with ASTM C406. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Galvanized fasteners shall be used for steel roofs. Wood shakes shall comply with the requirements of Table R905.8.5. Mineral-surfaced roll roofing shall not be applied on roof. General Re-Roof Requirements . Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Stainless steel fasteners are acceptable for metal roofs. Asphalt shingles shall comply with ASTM D3462. Self-adhering polymer-modified bitumen. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. 12 oz/sq ft for preformed metal shingle systems. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. See Table R503.2.1.1 for minimum allowable panel thickness by span and load.) Roof valley flashing shall be not less than No. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. hbbd```b``3@$R&5d}"uA$$X ,>,rLYfH 2o2dbO C"=Vbz CHEX/#300 k Asphalt shingles shall be fastened to solidly sheathed decks. SECTION R801 GENERAL. PDF Residential Roof Sheathing and Shear Walls or Braced Wall Panels Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Where the existing roof or roof covering is water-soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. Thermoset single-ply membrane roofs shall have a design. The installation of asphalt shingles shall comply with the provisions of this section. SECTION R803 ROOF SHEATHING. Foam plastic materials and installation shall comply with. The installation of asphalt shingles shall comply with the provisions of this section. Htt4 & -`P .+Yn0a|bZN4U+yX*iNFk $ Sprayed polyurethane foam roofs shall have a design. 201 0 obj <> endobj 2018 International Residential Code (Irc) | Icc Digital Codes R803.1 Lumber sheathing. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Liquid-applied roofing shall be installed in accordance with this chapter and the manufacturer's instructions. 260 0 obj <>stream The installation of mineral-surfaced roll roofing shall comply with this section. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Each bundle of shakes shall be identified by a. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Galvanized fasteners shall be used for steel roofs. The installation of asphalt shingles shall comply with the provisions of this section. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Chapter 9: Roof Assemblies, Residential Code 2018 of Nevada | UpCodes Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. Modified bitumen roofing shall comply with the standards in Table 905.11.2. Asphalt shingles shall be tested in accordance with ASTM D7158. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Where the existing roof has two or more applications of any type of roof covering. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of. RESIDENTIAL ROOFING GUIDE 2018 irc - Loveland, Colorado or less, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Chapter 9: Roof Assemblies, 2019 Residential Code of Ohio | UpCodes . PDF Guidelines for asphalt shingle roofing - Minnesota Slate shingles shall be fastened to solidly sheathed roofs. redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. The installation of built-up roofs shall comply with the provisions of this section. Wood shakes shall comply with the requirements of Table R905.8.5. The installation of liquid-applied roofing shall comply with the provisions of this section. Nails shall be corrosion resistant and not less than 11 gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. The installation of wood shakes shall comply with the provisions of this section. A base sheet that complies with the requirements of. PDF Roof Deck Requirements for Installation of Asphalt Shingles Technical

San Luis Obispo Obituaries 2021, Busted Paper Sullivan County Tn September 2020, The Lost Kitchen Farmers Market, Army Pulhes Requirements Mos, Articles OTHER

Comments are closed.